Practical Operation of Arc LampsNational carbon Company, 1911 - 75 σελίδες |
Αναζήτηση στο βιβλίο
Αποτελέσματα 1 - 5 από τα 10.
Σελίδα
... Insulation . Amperes . 18 1,624 3 16 2,583 6 Table B. Other Insulations . Amperes . 5 8 14 4,107 12 16 12 6,530 17 23 10 10,380 24 32 8 16,510 33 46 6 26,250 46 65 5 33,100 54 77 4 41,740 65 92 3 52,630 76 110 2 66,370 90 131 83,690 107 ...
... Insulation . Amperes . 18 1,624 3 16 2,583 6 Table B. Other Insulations . Amperes . 5 8 14 4,107 12 16 12 6,530 17 23 10 10,380 24 32 8 16,510 33 46 6 26,250 46 65 5 33,100 54 77 4 41,740 65 92 3 52,630 76 110 2 66,370 90 131 83,690 107 ...
Σελίδα 20
... insulation of the series coil . LAMP ADJUSTMENT . If an individual lamp gives short life for several trimmings , it is probable that it is out of adjustment and is operating at a high arc voltage . An examination of the carbons will ...
... insulation of the series coil . LAMP ADJUSTMENT . If an individual lamp gives short life for several trimmings , it is probable that it is out of adjustment and is operating at a high arc voltage . An examination of the carbons will ...
Σελίδα 41
... insulate it properly and allow sufficient clearances . Outside lamps may be suspended in three ways : 1 , placed on the top of the pole ; 2 , suspended from brackets at the side of the pole or building ; 3 , suspended on a wire ...
... insulate it properly and allow sufficient clearances . Outside lamps may be suspended in three ways : 1 , placed on the top of the pole ; 2 , suspended from brackets at the side of the pole or building ; 3 , suspended on a wire ...
Σελίδα 42
... insulation . The wires should be arranged to enter and leave the building through an approved double contact service ... insulated supports other than their conductors . Locating Troubles on Series Arc Lamp Circuits The three chief 42.
... insulation . The wires should be arranged to enter and leave the building through an approved double contact service ... insulated supports other than their conductors . Locating Troubles on Series Arc Lamp Circuits The three chief 42.
Σελίδα 43
... insulation supports the wire , giving no visible indication of trouble . This is liable to occur where the wire is dead ended to the insulator at the lamp . Grounds are of two kinds . The dead ground in which the circuit has permanent ...
... insulation supports the wire , giving no visible indication of trouble . This is liable to occur where the wire is dead ended to the insulator at the lamp . Grounds are of two kinds . The dead ground in which the circuit has permanent ...
Άλλες εκδόσεις - Προβολή όλων
Practical Operation of Arc Lamps Inc National Carbon Company Δεν υπάρχει διαθέσιμη προεπισκόπηση - 2023 |
The Practical Operation of ARC Lamps (Classic Reprint) National Carbon Company Inc Δεν υπάρχει διαθέσιμη προεπισκόπηση - 2017 |
Συχνά εμφανιζόμενοι όροι και φράσεις
A. C. lamps adjustment allow alternating current aluminum disc Ammeter amperes arc lamp circuits armature bons carbon holder carrying capacity cause the lamp choke coil circular mils clean clock feed lamp clutch conductor connected in series copper wire cored carbons cubic cuits Current Transformer cut-out D. C. circuits dash pot decagram decimeter diameter direct current Electrical enclosed arc lamps fed downward feet Flame Arc Lamps gas cap graphite ground heat high arc voltage horse power inch inclined carbon lamps inner globe insulation jump badly light Lightning Arresters line voltage lower carbon mean effective pressure mercury arc rectifier meters motor feed multiple lamp obtained operate Plug Switches position regulating mechanism regulating resistance series arc lamp series coil series lamps series magnet series multiple shown in Fig shunt coil side Specific Gravity square TABLE trimmer trimming tubes upper carbon usually vertical carbon lamp wattmeter weight
Δημοφιλή αποσπάσματα
Σελίδα 67 - Measures of Weight 10 milligrams (mg) =1 centigram eg 10 centigrams =1 decigram dg 10 decigrams =1 gram g 10 grams =1 dekagram Dg...
Σελίδα 49 - ... b. Must be placed at every point where a change is made in the size of wire [unless the cut-out in the larger wire will protect the smaller.
Σελίδα 67 - OF CAPACITY 10 milliliters (ml.) = 1 centiliter (cl.) 10 centiliters = 1 deciliter (dl.) 10 deciliters = 1 liter (1.) 10 liters = 1 dekaliter (Dl.) 10 dekaliters = 1 hektoliter (hi.) 10 hektoliters = 1 kiloliter (kl.) MEASURES OF WEIGHT 10 milligrams (mg.) = 1 centigram (eg.) 10 centigrams = 1 decigram (dg.) 10 decigrams = 1 gram (g.) 10 grams...
Σελίδα 48 - Wires must be so spliced or joined as to be both mechanically and electrically secure without solder. The joints must then be soldered unless made with some form of approved splicing device, and covered with an insulation equal to that on the conductors.
Σελίδα 67 - Measures of Length 10 millimeters (mm) =1 centimeter cm 10 centimeters =1 decimeter dm 10 decimeters =1 meter m 10 meters =1 dekameter Dm 10 dekameters =1 hektometer Hm 10 hektometers =1 kilometer Km...
Σελίδα 55 - The lower limit is specified for rubber-covered wires to prevent gradual deterioration of the high insulation* by the heat of the wires, but not from fear of igniting the insulation. The question of drop is not taken into consideration in the above tablea.
Σελίδα 64 - The Specific Gravity of a substance is the ratio of its weight to that of an equal volume of water.
Σελίδα 58 - The work done by a force acting obliquely on a moving body is measured by the product of the force and the distance through ivhich the body moves in the direction of the force.
Σελίδα 50 - ... systems must not at Central Stations be smaller than the neutral wire and not smaller than No. 6 B. & S.
Σελίδα 69 - Fahrenheit multiply by 1.8 and add 32. To convert degrees Fahrenheit to Centigrade, subtract 32 and divide the result by 1.8.