... lighting on account of the low voltage required . They may be connected directly across 110 and sometimes on 220 volt circuits . Fig . 1 . B Figure 1 shows the connections for a D. C. multiple lamp . There is only one set of magnet ...
... lighting on account of the low voltage required . They may be connected directly across 110 and sometimes on 220 volt circuits . Fig . 1 . B Figure 1 shows the connections for a D. C. multiple lamp . There is only one set of magnet ...
Σελίδα 6
... lamp , is used to cut down the line vol- tage to that required for the arc ... lamp from being short cir- cuited when the carbons are in contact . Although ... circuit when any repairs or adjustments are being made . The upper car- bon ...
... lamp , is used to cut down the line vol- tage to that required for the arc ... lamp from being short cir- cuited when the carbons are in contact . Although ... circuit when any repairs or adjustments are being made . The upper car- bon ...
Σελίδα 7
... lamp is adjusted for 80 volts at each arc . Fig.2 . L A. C. lamps may be operated on circuits of any fre- quency from 25 to 140 cycles . The standard for lighting is 60 cycles , and lamps operating on this frequency give better service ...
... lamp is adjusted for 80 volts at each arc . Fig.2 . L A. C. lamps may be operated on circuits of any fre- quency from 25 to 140 cycles . The standard for lighting is 60 cycles , and lamps operating on this frequency give better service ...
Σελίδα 8
... lamp mechanism will usually have to be made for changes in the frequency or current . This type of lamp is used on 110-120 volt circuits only and burns with an arc voltage of 72. All the magnet cores of the lamp are made of laminated ...
... lamp mechanism will usually have to be made for changes in the frequency or current . This type of lamp is used on 110-120 volt circuits only and burns with an arc voltage of 72. All the magnet cores of the lamp are made of laminated ...
Σελίδα 9
... lighting and for industrial plants . As many as 100 enclosed arc lamps are connected in series on one circuit . This would give a voltage of 100 x 75-7500 across the terminals of the circuit assuming a lamp voltage of 75. The line ...
... lighting and for industrial plants . As many as 100 enclosed arc lamps are connected in series on one circuit . This would give a voltage of 100 x 75-7500 across the terminals of the circuit assuming a lamp voltage of 75. The line ...
Άλλες εκδόσεις - Προβολή όλων
Practical Operation of Arc Lamps Inc National Carbon Company Δεν υπάρχει διαθέσιμη προεπισκόπηση - 2023 |
The Practical Operation of ARC Lamps (Classic Reprint) National Carbon Company Inc Δεν υπάρχει διαθέσιμη προεπισκόπηση - 2017 |
Συχνά εμφανιζόμενοι όροι και φράσεις
A. C. lamps adjustment allow alternating current aluminum disc Ammeter amperes arc lamp circuits armature bons carbon holder carrying capacity cause the lamp choke coil circular mils clean clock feed lamp clutch conductor connected in series copper wire cored carbons cubic cuits Current Transformer cut-out D. C. circuits dash pot decagram decimeter diameter direct current Electrical enclosed arc lamps fed downward feet Flame Arc Lamps gas cap graphite ground heat high arc voltage horse power inch inclined carbon lamps inner globe insulation jump badly light Lightning Arresters line voltage lower carbon mean effective pressure mercury arc rectifier meters motor feed multiple lamp obtained operate Plug Switches position regulating mechanism regulating resistance series arc lamp series coil series lamps series magnet series multiple shown in Fig shunt coil side Specific Gravity square TABLE trimmer trimming tubes upper carbon usually vertical carbon lamp wattmeter weight
Δημοφιλή αποσπάσματα
Σελίδα 67 - Measures of Weight 10 milligrams (mg) =1 centigram eg 10 centigrams =1 decigram dg 10 decigrams =1 gram g 10 grams =1 dekagram Dg...
Σελίδα 49 - ... b. Must be placed at every point where a change is made in the size of wire [unless the cut-out in the larger wire will protect the smaller.
Σελίδα 67 - OF CAPACITY 10 milliliters (ml.) = 1 centiliter (cl.) 10 centiliters = 1 deciliter (dl.) 10 deciliters = 1 liter (1.) 10 liters = 1 dekaliter (Dl.) 10 dekaliters = 1 hektoliter (hi.) 10 hektoliters = 1 kiloliter (kl.) MEASURES OF WEIGHT 10 milligrams (mg.) = 1 centigram (eg.) 10 centigrams = 1 decigram (dg.) 10 decigrams = 1 gram (g.) 10 grams...
Σελίδα 48 - Wires must be so spliced or joined as to be both mechanically and electrically secure without solder. The joints must then be soldered unless made with some form of approved splicing device, and covered with an insulation equal to that on the conductors.
Σελίδα 67 - Measures of Length 10 millimeters (mm) =1 centimeter cm 10 centimeters =1 decimeter dm 10 decimeters =1 meter m 10 meters =1 dekameter Dm 10 dekameters =1 hektometer Hm 10 hektometers =1 kilometer Km...
Σελίδα 55 - The lower limit is specified for rubber-covered wires to prevent gradual deterioration of the high insulation* by the heat of the wires, but not from fear of igniting the insulation. The question of drop is not taken into consideration in the above tablea.
Σελίδα 64 - The Specific Gravity of a substance is the ratio of its weight to that of an equal volume of water.
Σελίδα 58 - The work done by a force acting obliquely on a moving body is measured by the product of the force and the distance through ivhich the body moves in the direction of the force.
Σελίδα 50 - ... systems must not at Central Stations be smaller than the neutral wire and not smaller than No. 6 B. & S.
Σελίδα 69 - Fahrenheit multiply by 1.8 and add 32. To convert degrees Fahrenheit to Centigrade, subtract 32 and divide the result by 1.8.