Practical Operation of Arc LampsNational carbon Company, 1911 - 75 σελίδες |
Αναζήτηση στο βιβλίο
Αποτελέσματα 1 - 5 από τα 14.
Σελίδα 5
... the arc is the proper length , the magnets are not strong enough to raise the upper car- bon further . As the carbons are burned away the magnets are weakened and the clutch rod slowly descends until the clutch strikes the stop and 5.
... the arc is the proper length , the magnets are not strong enough to raise the upper car- bon further . As the carbons are burned away the magnets are weakened and the clutch rod slowly descends until the clutch strikes the stop and 5.
Σελίδα 6
... length of the arc will not cause such great varia- tions . It also prevents the lamp from being short cir- cuited when the carbons are in contact . Although not shown in the figure , a dash pot should be provided to deaden the movement ...
... length of the arc will not cause such great varia- tions . It also prevents the lamp from being short cir- cuited when the carbons are in contact . Although not shown in the figure , a dash pot should be provided to deaden the movement ...
Σελίδα 9
... length of the arc , it is evident that a series coil alone cannot regulate this lamp . Fig . 5 shows the connections , for an A. C. series lamp . Owing to the difficulty of generating D. C. at the high voltage required , comparatively ...
... length of the arc , it is evident that a series coil alone cannot regulate this lamp . Fig . 5 shows the connections , for an A. C. series lamp . Owing to the difficulty of generating D. C. at the high voltage required , comparatively ...
Σελίδα 10
... length of the arc is reached it equalizes the series magnet . As the carbons are consumed the shunt magnet becomes stronger than the series and lowers the carbon . If the carbon fails to feed and the arc becomes too long , the shunt ...
... length of the arc is reached it equalizes the series magnet . As the carbons are consumed the shunt magnet becomes stronger than the series and lowers the carbon . If the carbon fails to feed and the arc becomes too long , the shunt ...
Σελίδα 13
... length of time on a cement floor having an earth foundation . If they must be stored in such a place , put boards under them so as to allow free circulation of air . Trimmers should use a covered bag to protect the car- bons from dust ...
... length of time on a cement floor having an earth foundation . If they must be stored in such a place , put boards under them so as to allow free circulation of air . Trimmers should use a covered bag to protect the car- bons from dust ...
Άλλες εκδόσεις - Προβολή όλων
Practical Operation of Arc Lamps Inc National Carbon Company Δεν υπάρχει διαθέσιμη προεπισκόπηση - 2023 |
The Practical Operation of ARC Lamps (Classic Reprint) National Carbon Company Inc Δεν υπάρχει διαθέσιμη προεπισκόπηση - 2017 |
Συχνά εμφανιζόμενοι όροι και φράσεις
A. C. lamps adjustment allow alternating current aluminum disc Ammeter amperes arc lamp circuits armature bons carbon holder carrying capacity cause the lamp choke coil circular mils clean clock feed lamp clutch conductor connected in series copper wire cored carbons cubic cuits Current Transformer cut-out D. C. circuits dash pot decagram decimeter diameter direct current Electrical enclosed arc lamps fed downward feet Flame Arc Lamps gas cap graphite ground heat high arc voltage horse power inch inclined carbon lamps inner globe insulation jump badly light Lightning Arresters line voltage lower carbon mean effective pressure mercury arc rectifier meters motor feed multiple lamp obtained operate Plug Switches position regulating mechanism regulating resistance series arc lamp series coil series lamps series magnet series multiple shown in Fig shunt coil side Specific Gravity square TABLE trimmer trimming tubes upper carbon usually vertical carbon lamp wattmeter weight
Δημοφιλή αποσπάσματα
Σελίδα 67 - Measures of Weight 10 milligrams (mg) =1 centigram eg 10 centigrams =1 decigram dg 10 decigrams =1 gram g 10 grams =1 dekagram Dg...
Σελίδα 49 - ... b. Must be placed at every point where a change is made in the size of wire [unless the cut-out in the larger wire will protect the smaller.
Σελίδα 67 - OF CAPACITY 10 milliliters (ml.) = 1 centiliter (cl.) 10 centiliters = 1 deciliter (dl.) 10 deciliters = 1 liter (1.) 10 liters = 1 dekaliter (Dl.) 10 dekaliters = 1 hektoliter (hi.) 10 hektoliters = 1 kiloliter (kl.) MEASURES OF WEIGHT 10 milligrams (mg.) = 1 centigram (eg.) 10 centigrams = 1 decigram (dg.) 10 decigrams = 1 gram (g.) 10 grams...
Σελίδα 48 - Wires must be so spliced or joined as to be both mechanically and electrically secure without solder. The joints must then be soldered unless made with some form of approved splicing device, and covered with an insulation equal to that on the conductors.
Σελίδα 67 - Measures of Length 10 millimeters (mm) =1 centimeter cm 10 centimeters =1 decimeter dm 10 decimeters =1 meter m 10 meters =1 dekameter Dm 10 dekameters =1 hektometer Hm 10 hektometers =1 kilometer Km...
Σελίδα 55 - The lower limit is specified for rubber-covered wires to prevent gradual deterioration of the high insulation* by the heat of the wires, but not from fear of igniting the insulation. The question of drop is not taken into consideration in the above tablea.
Σελίδα 64 - The Specific Gravity of a substance is the ratio of its weight to that of an equal volume of water.
Σελίδα 58 - The work done by a force acting obliquely on a moving body is measured by the product of the force and the distance through ivhich the body moves in the direction of the force.
Σελίδα 50 - ... systems must not at Central Stations be smaller than the neutral wire and not smaller than No. 6 B. & S.
Σελίδα 69 - Fahrenheit multiply by 1.8 and add 32. To convert degrees Fahrenheit to Centigrade, subtract 32 and divide the result by 1.8.