Practical Operation of Arc LampsNational carbon Company, 1911 - 75 σελίδες |
Αναζήτηση στο βιβλίο
Αποτελέσματα 1 - 5 από τα 14.
Σελίδα 6
... placed on top of the upper carbon holder . The switch on the top of the lamp is used to open the circuit when any repairs or adjustments are being made . The upper car- bon holder slides within a tube and connection is usually made to ...
... placed on top of the upper carbon holder . The switch on the top of the lamp is used to open the circuit when any repairs or adjustments are being made . The upper car- bon holder slides within a tube and connection is usually made to ...
Σελίδα 7
... placed side by side and connected in series as shown in Fig . 2. Both pairs of car- bons are controlled by the same regulating mechanism . The best results will be obtained if the lamp is adjusted for 80 volts at each arc . Fig.2 . L ...
... placed side by side and connected in series as shown in Fig . 2. Both pairs of car- bons are controlled by the same regulating mechanism . The best results will be obtained if the lamp is adjusted for 80 volts at each arc . Fig.2 . L ...
Σελίδα 14
... placed in the lamp with the burned end to the arc . This brings the lamp to full candle power in a minimum length of time and sometimes prevents flaming and possible globe breakage . In the D. C. lamp the upper carbon should always be ...
... placed in the lamp with the burned end to the arc . This brings the lamp to full candle power in a minimum length of time and sometimes prevents flaming and possible globe breakage . In the D. C. lamp the upper carbon should always be ...
Σελίδα 21
... placed in service , and afterwards at regular intervals to see that no screws are loose and that all parts are in good condition . There is a continual tendency , especially in the A. C. lamp , for the connections to become loose ...
... placed in service , and afterwards at regular intervals to see that no screws are loose and that all parts are in good condition . There is a continual tendency , especially in the A. C. lamp , for the connections to become loose ...
Σελίδα 29
... placed directly across 110 volts . A. C. lamps are sometimes operated from constant potential circuits of 110 to 550 volts through a compensator or transformer hung directly above the lamp . In most cases the lamps connected in series ...
... placed directly across 110 volts . A. C. lamps are sometimes operated from constant potential circuits of 110 to 550 volts through a compensator or transformer hung directly above the lamp . In most cases the lamps connected in series ...
Άλλες εκδόσεις - Προβολή όλων
Practical Operation of Arc Lamps Inc National Carbon Company Δεν υπάρχει διαθέσιμη προεπισκόπηση - 2023 |
The Practical Operation of ARC Lamps (Classic Reprint) National Carbon Company Inc Δεν υπάρχει διαθέσιμη προεπισκόπηση - 2017 |
Συχνά εμφανιζόμενοι όροι και φράσεις
A. C. lamps adjustment allow alternating current aluminum disc Ammeter amperes arc lamp circuits armature bons carbon holder carrying capacity cause the lamp choke coil circular mils clean clock feed lamp clutch conductor connected in series copper wire cored carbons cubic cuits Current Transformer cut-out D. C. circuits dash pot decagram decimeter diameter direct current Electrical enclosed arc lamps fed downward feet Flame Arc Lamps gas cap graphite ground heat high arc voltage horse power inch inclined carbon lamps inner globe insulation jump badly light Lightning Arresters line voltage lower carbon mean effective pressure mercury arc rectifier meters motor feed multiple lamp obtained operate Plug Switches position regulating mechanism regulating resistance series arc lamp series coil series lamps series magnet series multiple shown in Fig shunt coil side Specific Gravity square TABLE trimmer trimming tubes upper carbon usually vertical carbon lamp wattmeter weight
Δημοφιλή αποσπάσματα
Σελίδα 67 - Measures of Weight 10 milligrams (mg) =1 centigram eg 10 centigrams =1 decigram dg 10 decigrams =1 gram g 10 grams =1 dekagram Dg...
Σελίδα 49 - ... b. Must be placed at every point where a change is made in the size of wire [unless the cut-out in the larger wire will protect the smaller.
Σελίδα 67 - OF CAPACITY 10 milliliters (ml.) = 1 centiliter (cl.) 10 centiliters = 1 deciliter (dl.) 10 deciliters = 1 liter (1.) 10 liters = 1 dekaliter (Dl.) 10 dekaliters = 1 hektoliter (hi.) 10 hektoliters = 1 kiloliter (kl.) MEASURES OF WEIGHT 10 milligrams (mg.) = 1 centigram (eg.) 10 centigrams = 1 decigram (dg.) 10 decigrams = 1 gram (g.) 10 grams...
Σελίδα 48 - Wires must be so spliced or joined as to be both mechanically and electrically secure without solder. The joints must then be soldered unless made with some form of approved splicing device, and covered with an insulation equal to that on the conductors.
Σελίδα 67 - Measures of Length 10 millimeters (mm) =1 centimeter cm 10 centimeters =1 decimeter dm 10 decimeters =1 meter m 10 meters =1 dekameter Dm 10 dekameters =1 hektometer Hm 10 hektometers =1 kilometer Km...
Σελίδα 55 - The lower limit is specified for rubber-covered wires to prevent gradual deterioration of the high insulation* by the heat of the wires, but not from fear of igniting the insulation. The question of drop is not taken into consideration in the above tablea.
Σελίδα 64 - The Specific Gravity of a substance is the ratio of its weight to that of an equal volume of water.
Σελίδα 58 - The work done by a force acting obliquely on a moving body is measured by the product of the force and the distance through ivhich the body moves in the direction of the force.
Σελίδα 50 - ... systems must not at Central Stations be smaller than the neutral wire and not smaller than No. 6 B. & S.
Σελίδα 69 - Fahrenheit multiply by 1.8 and add 32. To convert degrees Fahrenheit to Centigrade, subtract 32 and divide the result by 1.8.