" Wires must be so spliced or joined as to be both mechanically and electrically secure without solder. The joints must then be soldered unless made with some form of approved splicing device, and covered with an insulation equal to that on the conductors. "
Practical Operation of Arc Lamps - Σελίδα 48
των National Carbon Company, Inc - 1911 - 75 σελίδες
Πλήρης προβολή - Σχετικά με αυτό το βιβλίο

Telegraphic Journal and Monthly Illustrated Review of Electrical ..., Τόμος 8

1891 - 680 σελίδες
...with petticoat insulators of glass or porcelain. Porcelain knobs and rubber hooks are prohibited. 7. So spliced or joined as to be both mechanically and electrically secure without solder. They must then be soldered to ensure preservation, and covered with an insulation equal to that on...

The Architect's and Builder's Pocket-book of Mensuration, Geometry ...

Frank Eugene Kidder - 1892 - 1058 σελίδες
...insulators of glass or porcelain. Porcelain knobs or cleats and rubber hooks will not be approved. (/) Must be so spliced or joined as to be both mechanically...with an insulation equal to that on the conductors. 11. Service Blocks : (a) Must lie covered over their entire surface with at least two coats of waterproof...

Electric Lighting Specifications for the Use of Engineers and Architects

Earle Abbott Merrill - 1892 - 188 σελίδες
...prohibited. 7. So spliced or joined as to be both mechanically and electrically secure without solder. They must then be soldered to insure preservation, and...with an insulation equal to that on the conductors. The following formula for soldering fluid is approved : Saturated solution of zinc . . 5 parts. Alcohol...

The Architect's and Builder's Pocket-book of Mensuration, Geometry ...

Frank Eugene Kidder - 1892 - 1032 σελίδες
...partitions through which they may pass, by non-combustible insulating tube or hard rubber tube. (g) Must be so spliced or joined as to be both mechanically and electrically secure without solder. They must then be soldered, to insure preservation, and covered with an insulation equal to that on...

Electric Lighting Specifications for the Use of Engineers and Architects

Earle Abbott Merrill - 1892 - 188 σελίδες
...with petticoat insulators of glass or porcelain. Porcelain knobs and rubber hooks are prohibited. 7. So spliced or joined as to be both mechanically and electrically secure without solder. They must then be soldered to insure preservation, and covered with an insulation equal to that on...

Convention

National Electric Light Association. Convention - 1892 - 458 σελίδες
...with petticoat insulators of glass or porcelain. Porcelain knobs and rubber hooks are prohibited. 7. So spliced or joined as to be both mechanically and electrically secure without solder. They must then be soldered to insure preservation, and covered with an insulation equal to that on...

Standard Tables for Electric Wiremen: With Instructions for Wiremen and ...

Charles M. Davis - 1893 - 162 σελίδες
...or partitions through which they may pass by non-combustible insulating tube or hard-rubber tube. g. Must be so spliced or joined as to be both mechanically and electrically secure without solder. They must then be soldered to insure preservation, and covered with an insulation equal to that on...

Electrical Engineer, Τόμος 17

1894 - 620 σελίδες
...petticoat insulators of glass or porcelain. Porcelain knob«, cleat« and rubber hooks are prohibited. 7. Must be so spliced or joined as to be both mechanically and electrically secure without solder. They must then be soldered to Insure preservation and covered with an insulation equal to that on the...

New Catechism of Electricity: A Practical Treatise

Nehemiah Hawkins - 1896 - 570 σελίδες
...insulators of glass or porcelain. Porcelain knobs or cleats and rubber hooks will not be approved. f. Must be so spliced or joined as to be both mechanically...with an insulation equal to that on the conductors. (See Definitions. ) g. Telegraph, telephone and similar wires must not be placed on the same cross-arm...

Electric Wiring for the Use of Architects, Underwriters, and the Owners of ...

Russell Robb - 1896 - 206 σελίδες
...walls, floors, timbers or partitions through which they may pass, by noncombustible insulating tube. g. Must be so spliced or joined as to be both mechanically and electrically secure without solder. They must then be soldered, to insure preservation, and covered -with an insulation equal to that on...