Specifications, Tolerances and Regulations for Commercial Weights and Measures and Weighing and Measuring DevicesU.S. Government Printing Office, 1955 |
Αναζήτηση στο βιβλίο
Αποτελέσματα 1 - 5 από τα 21.
Σελίδα 2
... practicable to the official standards , weights and measures and weighing and measuring devices that are false , that are of such construction that they are faulty - that is , that are not reasonably permanent in their adjustment or ...
... practicable to the official standards , weights and measures and weighing and measuring devices that are false , that are of such construction that they are faulty - that is , that are not reasonably permanent in their adjustment or ...
Σελίδα 3
... practicable date . In earlier compilations of the specifications published prior to 1949 , the nonretroactive character of specifications orig- inally so classified was retained , regardless of the time that may have elapsed since ...
... practicable date . In earlier compilations of the specifications published prior to 1949 , the nonretroactive character of specifications orig- inally so classified was retained , regardless of the time that may have elapsed since ...
Σελίδα 10
... practicable to zero error . Toler- ances are primarily accuracy criteria for use by the regulatory official . Equipment owners should never be permitted to take advantage of tolerances by deliberately adjusting their equipment to have a ...
... practicable to zero error . Toler- ances are primarily accuracy criteria for use by the regulatory official . Equipment owners should never be permitted to take advantage of tolerances by deliberately adjusting their equipment to have a ...
Σελίδα 11
... practicable the full benefit of its own tolerance . Field testing operations are complicated to some degree when corrections to standards are applied , and except for work of relatively high precision it is recommended that the accuracy ...
... practicable the full benefit of its own tolerance . Field testing operations are complicated to some degree when corrections to standards are applied , and except for work of relatively high precision it is recommended that the accuracy ...
Σελίδα 21
... practicable to mark or tag as " rejected " each item of equipment found to be incorrect and considered susceptible of proper reconditioning , and this should always be done unless the repairs are to be begun immediately . However , the ...
... practicable to mark or tag as " rejected " each item of equipment found to be incorrect and considered susceptible of proper reconditioning , and this should always be done unless the repairs are to be begun immediately . However , the ...
Άλλες εκδόσεις - Προβολή όλων
Συχνά εμφανιζόμενοι όροι και φράσεις
1961 Replacement Sheet acceptance tolerances adjustable apothecaries applied automatic automatic-indicating scale avoirdupois AXLE-LOAD beam bottle Bureau of Standards commercial equipment commercial weighing compartment computing Conference on Weights correct CREAM-TEST cubic inches delivery designed dry measures error fluid drams fluid ounces fluid scruple gallon grain hose hundredweight incl indicating or recording installation kilogram large-capacity scale less liquefied petroleum gas liquid-measuring devices livestock load-receiving element maintenance tolerances marked maximum maintenance means measure-containers measures official measuring devices ment meter milligrams milliliters minimum discharge rate minimum graduated interval MOISTURE-TEST SCALES money value money-value motor-fuel device National Bureau National Conference nominal capacity Nominal value nonretroactive normal odometer one-half operation overregistration percent position pounds PRESCRIPTION SCALES quart railway track scales reading-face recorded representations recording elements regulations retail device SCALE.-A SCALE.-One SCALES.-The seal shown in table square taximeter test load tions TROY WEIGHTS underregistration vehicle tank weighing scale weights and measures wholesale device
Δημοφιλή αποσπάσματα
Σελίδα 153 - Square Measure 144 square inches (sq. in.) = 1 square foot (sq. ft.) 9 square feet = 1 square yard (sq.
Σελίδα 155 - Dry Measure. — 2 pints = 1 quart; 8 quarts = 1 peck; 4 pecks = 1 bushel.
Σελίδα 153 - Cubic Measure 1728 cubic inches (cu. in.) =1 cubic foot (cu. ft.) 27 cubic feet = 1 cubic yard (cu. yd.) 128 cubic feet = 1 cord (cd...
Σελίδα 39 - ... that is not so positioned that its indications may be accurately read and the weighing or measuring operation observed from some position which may reasonably be assumed by a customer. (9) Violate any provision of this Act or of the regulations promulgated under the provisions of this Act for which a specific penalty has not been prescribed.
Σελίδα 167 - The weight in milligrams ot precious metal obtained from one assay ton of ore gives directly the number of troy ounces to the net ton.
Σελίδα 29 - ... in proving the size, quantity, extent, area, or measurement of quantities, things, produce, or articles for distribution or consumption purchased or offered or submitted by such person or persons for sale, hire, or award...
Σελίδα 156 - Linear Measure 10 millimeters (mm) = 1 centimeter (cm) 10 centimeters = 1 decimeter (dm) = 100 millimeters 10 decimeters = 1 meter (m) = 1,000 millimeters 10 meters = 1 dekameter (dam...
Σελίδα 91 - ... the name and address of the person, firm or corporation, to whom the applicant is referred or sent for work or employment.
Σελίδα 154 - LIQUID MEASURE When necessary to distinguish the liquid pint or quart from the dry pint or quart, the word "liquid" or the abbreviation "liq" should be used in combination with the name or abbreviation of the liquid unit.
Σελίδα 36 - ... finest graduations with which it is used, unless the indicator and the graduations are in the same plane, in which case the distance between the end of the indicator and the ends of the graduations, measured along the line of the graduations, shall be not more than 0.04 inch.