" Should any such test bar fail in either the tensile or bending test, no bars from such heat shall be allowed to be used in the construction of any marine boiler. Where a heat of steel bars has been passed by an inspector, separate lots... "
Henley's Encyclopædia of Practical Engineering and Allied Trades: A ... - Σελίδα 220
επεξεργασία από - 1906
Πλήρης προβολή - Σχετικά με αυτό το βιβλίο

A Text Book of Naval Architecture: For the Use of Officers of the Royal Navy

John Joseph Welch - 1891 - 216 σελίδες
...the specimens so treated must stand being bent double in a press to a curve of which the inner radius is equal to one and a half times the thickness of the plate tested. Moulded steel is also subjected to hot and cold forge tests to prove its fitness for service....

Steam-boiler Construction: A Practical Handbook for Engineers, Boiler-makers ...

Walter S. Hutton - 1891 - 544 σελίδες
...the surveyor. The test-pieces are heated to a low cherry-red, and cooled in water of 82° Fahr. They must then stand bending to a curve, the inner radius of which is one and a half times the thickness of the piece. All plates passed by Lloyd's surveyors are branded,...

Architectural Engineering: With Special Reference to High Building ...

Joseph Kendall Freitag - 1895 - 268 σελίδες
...Test. — Duplicate specimens will be required to stand bending 180° around a mandrel, the diameter of which is equal to one and a half times the thickness of the specimen, without showing signs of rupture on either concave or convex side. After being heated to...

Practical Marine Engineering for Marine Engineers and Students: With Aids ...

William Frederick Durand - 1901 - 738 σελίδες
...manner : Inspectors shall promiscuously select one bar from each lot and bend one end of such bar cold to a curve, the inner radius of which is equal to one and one-half times the diameter of the test bar ; and should any such test bar break in the bending process...

Steam-boilers: Their Theory and Design

Harry de Berkeley Parsons - 1903 - 396 σελίδες
...manner: Inspectors shall promiscuously select' one bar from each lot and bend one end of such bar cold to a curve the inner radius of which is equal to one and one-half times the diameter of the test-bar; and should any such test-bar break in the bending process...

Henley's Encyclopaedia of Practical Engineering and Allied Trades ...

1906 - 576 σελίδες
...classes of plates is the bending test, in which a shearing is taken about 10 in. or 11 in. long by 1 i in. wide, heated to a low cherry red, and cooled in...before being worked up, tests which were not insisted Boi riven nom iour-speeu cone puueys ^IIUL iown), but the radial drill has a separate Г1! ' 1 1 I...

Henley's Encyclopaedia of Practical Engineering and Allied Trades ...

1906 - 576 σελίδες
...Samples are also to be heated to a low cherry red and cooled in water of 82° Fahr., and then bent to a curve the inner radius of which is equal to one and a half times the thickness of the plate. Tests of other inspecting bodies do not vary much from the above. They are summarised below. British...

General Rules and Regulations Prescribed by the Board of Supervising ...

United States. Department of Commerce and Labor. Steamboat Inspection Service - 1906 - 154 σελίδες
...manner: Inspectors shall select one bar or brace from each lot and bend one end of such bar or brace cold to a curve, the inner radius of which is equal to one and. onehalf times the diameter of the test bars or the thickness of the brace, as the case may be, without...

I.C.S. Reference Library: A Series of Textbooks ...

1907 - 668 σελίδες
...the bar. Steel bars for stays or braces must also pass a bending test; the sample is to be bent cold to a curve the inner radius of which is equal to one and one-half times the diameter of the bar, and must stand this bending without showing flaws or cracks....

International Library of Technology: A Series of Textbooks ..., Τόμος 9,Μέρος 2

1907 - 636 σελίδες
...steel bars to be used for stays or braces must pass a cold bending test; the sample is to be bent cold to a curve the inner radius of which is equal to one and one-half times the diameter or thickness of the bar, and must stand this bending without showing flaws...