" Charge and Discharge Characteristics — The cell under test must be fully charged before beginning the experiment on discharge characteristics. The end of the charge is best recognized by the density of the acid, which reaches its maximum and remains... "
Industrial Engineering and the Engineering Digest - Σελίδα 561
1907
Πλήρης προβολή - Σχετικά με αυτό το βιβλίο

Experimental Electrical Engineering and Manual for Electrical Testing; for ...

Vladimir Karapetoff - 1907 - 852 σελίδες
...by the density of the acid, which reaches its maximum and remains constant. The voltage also reaches its maximum and remains constant. The absolute values...discharged. At a higher rate of charging, the electrolyte heats up and the liberated gases cause it to boil; with the result that active material is washed out...

Experimental Electrical Engineering and Manual for Electrical ..., Τόμος 1

Vladimir Karapetoff - 1910 - 582 σελίδες
...by the density of the acid, which reaches its maximum and remains constant. The voltage also reaches its maximum and remains constant. The absolute values...usually given by the manufacturer of the cell, and may van' within certain limits. The time of charging should not be less than three hours if the cell has...

Decisions of the Commissioner of Patents and of the United States Courts in ...

United States. Patent Office - 1948 - 604 σελίδες
...under test must be fully charged before beginning the experiment on the discharge characteristics, and "The time of charging should not be less than three hours if the cell has been completely discharged." The patent to Oestermeyer relates to testers for various circuits...

Court of Customs and Patent Appeals Reports

United States. Court of Customs and Patent Appeals - 1946 - 564 σελίδες
...under test must be fully charged before beginning the experiment on the discharge characteristics, and "The time of charging should not be less than three hours if the cell has been completely discharged." The patent to Oestermeyer relates to testers for various circuits...

The Electric Journal, Τόμος 4

1907 - 900 σελίδες
...by the density of the acid, which reaches its maximum and remains constant. The voltage also reaches its maximum and remains constant. The absolute values...charging should not be less than three hours if the batten' has been completely discharged. At a higher rate of charging, the electrolyte warms up and...