" See that the boiler is thoroughly heated before the trial to its usual working temperature. If the boiler is new and of a form provided with a brick setting, it should be in regular use at least a week before the trial, so as to dry and heat the walls.... "
The Mechanical Engineer's Pocket-book: A Reference Book of Rules, Tables ... - Σελίδα 691
των William Kent - 1902 - 1129 σελίδες
Πλήρης προβολή - Σχετικά με αυτό το βιβλίο

Experimental Engineering and Manual for Testing: For Engineers and for ...

Rolla Clinton Carpenter - 1892 - 830 σελίδες
...the markets. APPENDIX. 7 form provided with a brick setting, it should he in regular use at least a week before the trial, so as to dry and heat the walls....before the trial until the walls are well heated. VII. Th'! bailor and fonnidions should be proved to be free from leaks before beginning a test, and all...

Modern Mechanism: Exhibiting the Latest Progress in Machines, Motors, and ...

Park Benjamin - 1892 - 962 σελίδες
...heat the walls. "VIII. Before beginning a test the boiler and connections should be free from leaks, and all water connections, including blow and extra feed-pipes, should be disconnected or stopped with blank flanges, except the particular pipe through which water is to be fed to the boiler...

Modern Mechanism: Exhibiting the Latest Progress in Machines, Motors, and ...

Park Benjamin - 1892 - 970 σελίδες
...heat the walls. "VIII. Before beginning a test the boiler and connections should be free from leaks, and all water connections, including blow and extra feed-pipes, should be disconnected or stopped with blank flanges, except the particular pipe through which water is to be fed to the boiler...

The Heat Efficiency of Steam Boilers: Land Marine and Locomotive: With Tests ...

Bryan Donkin - 1898 - 340 σελίδες
...boiler is new, and of a form provided with a brick setting, it should be in regular use at least a week before the trial, so as to dry and heat the walls....and all water connections, including blow and extra feed pipes, should be disconnected, stopped with blank flanges, or led through special openings beyond...

The Heat Efficiency of Steam Boilers: Land Marine and Locomotive: With Tests ...

Bryan Donkin - 1898 - 344 σελίδες
...boiler is new, and of a form provided with a brick setting, it should be in regular use at least a week before the trial, so as to dry and heat the walls....the trial until the walls are well heated. VII. The hotter and connections should be proved to be free from leaks before beginning a test, and all water...

A Handbook of Engineering Laboratory Practice

Richard Addison Smart - 1898 - 328 σελίδες
...heat the walls. VIII. Before beginning a test, the boiler and connections should be free from leaks, and all water connections, including blow- and extra feed-pipes, should be disconnected or stopped with blank flanges, except the particular pipe through which water is to be fed to the boiler...

Steam-boiler Practice: In Its Relation to Fuels and Their Combustion and the ...

Walter Bradlee Snow - 1899 - 340 σελίδες
...markets. boiler is new and of a form provided with a brick setting, it should be in regular use at least a week before the trial, so as to dry and heat the walls....should be disconnected, stopped with blank flanges, or bled through special openings beyond the valves, except the particular pipe through which water is...

The Calorific Power of Fuels: With a Collection of Auxiliary Tables, and ...

Herman Poole - 1900 - 330 σελίδες
...various .grates, boilers, and methods of tiring, and wide distributio bility in the markets. at least a week before the trial, so as to dry and heat the walls....and all water connections, including blow and extra feed pipes, should be disconnected, stopped with blank flanges, or bled through special openings beyond...

ASME Transactions, Τόμος 21

American Society of Mechanical Engineers - 1900 - 1252 σελίδες
...accessibility in the markets. form provided with a brick setting, it should be in regular use at least a week before the trial, so as to dry and heat the walls....and all water connections, including blow and extra feed pipes, should be disconnected, stopped with blank flanges, or bled through special openings beyond...

The Calorific Power of Fuels: With a Collection of Auxiliary Tables, and ...

Herman Poole - 1900 - 342 σελίδες
...of firing, aud wide distribution and general accessibility in the markets. APPENDIX. 183 at least a week before the trial, so as to dry and heat the walls....before the trial until the walls are well heated. YII. The boiler and connections should be proved to be free from leaks before beginning a test, and...