... limits . For instance , in Fig . 2 are shown an iron rod A and a copper rod B , both resting on pedestals . Both rods are of the same length , 1 ft . , and of the same cross - section . Each has one end in the same gas flame ,
... limits . For instance , in Fig . 2 are shown an iron rod A and a copper rod B , both resting on pedestals . Both rods are of the same length , 1 ft . , and of the same cross - section . Each has one end in the same gas flame ,
Σελίδα 4
... flame of each rod , those on the copper will burn earlier than those on the iron rod . 2. Convection . - The hot air ... flame is applied on one side , becomes equally heated throughout . First of all , the water just over the flame ...
... flame of each rod , those on the copper will burn earlier than those on the iron rod . 2. Convection . - The hot air ... flame is applied on one side , becomes equally heated throughout . First of all , the water just over the flame ...
Σελίδα 48
... flame consists of two parts , a small inner cone flame bluish - white in color and a large , non - luminous FIG . 38 . enveloping flame . The tempera- ture of the inner cone is 6,300 ° F . Acetylene is generated by the addition of ...
... flame consists of two parts , a small inner cone flame bluish - white in color and a large , non - luminous FIG . 38 . enveloping flame . The tempera- ture of the inner cone is 6,300 ° F . Acetylene is generated by the addition of ...
Σελίδα 50
... torch with a torch lighter . 13. Open oxygen valve on torch wide , and adjust regulator with gas flow . 14. Adjust torch valves to secure neutral flame . ACETYLENE AV 15. For a temporary stop , close the. 50 PLUMBERS ' HANDBOOK.
... torch with a torch lighter . 13. Open oxygen valve on torch wide , and adjust regulator with gas flow . 14. Adjust torch valves to secure neutral flame . ACETYLENE AV 15. For a temporary stop , close the. 50 PLUMBERS ' HANDBOOK.
Σελίδα 51
... the manufacturer of torches . On Page 61 is given a table showing the thickness of metal that can be welded with a given sized tip . OXYGEN K HG Welding Flame . - The flame necessary to produce the. OXYACETYLENE WELDING 51.
... the manufacturer of torches . On Page 61 is given a table showing the thickness of metal that can be welded with a given sized tip . OXYGEN K HG Welding Flame . - The flame necessary to produce the. OXYACETYLENE WELDING 51.
Άλλες εκδόσεις - Προβολή όλων
Συχνά εμφανιζόμενοι όροι και φράσεις
acetylene acid allowed alloy amount angle bend board or bureau boiler brass building calcium sulfate carbon cast iron CAST-IRON DRAINAGE FITTINGS cent chaser chimney coating cock column connection copper corrosion cubic cubic foot diameter Dimension discharge dissolved elbow enter eutectic fixtures flame flange floor flush foot furnace gage gallons galvanized gases heat heater house drain hydrogen inlet installed joints lead lead crystals less manganese material melting metal molten nitric acid outlet oxide oxygen pattern phosphorus placed plumbing pounds pressure pump radiator roof seam sewer shown in Fig side slag solder solution space square inch steam steel sulfur sulfuric acid supply surface TABLE tank temperature thread pipe threads toilet rooms trap tube urinal valve vent wall waste pipe water closets Weight of bundle Weight of sheet welding wrought iron zinc
Δημοφιλή αποσπάσματα
Σελίδα 522 - Measures of Length. 10 millimeters (mm.) 1 centimeter (cm.) 10 centimeters 1 decimeter (dm.) 10 decimeters 1 meter (m.) 10 meters 1 dekameter (Dm.) 10 dekameters 1 hectometer (Hm.) 10 hectometers 1 kilometer (Km.) 10 kilometers 1 myriameter (Mm.) 1181.
Σελίδα 605 - All connections of lead with iron pipes must be made with a brass sleeve or ferrule of the same size as the lead pipe, put in the hub of the branch of the iron pipe, and caulked with lead. The lead pipe must be attached to the ferrule by a wiped or overcast joint.
Σελίδα 179 - ... larger than those shown in the table are measured by the outside diameter and will be furnished with plain ends unless otherwise specified; for such sizes it will be necessary to accept Manufacturers' weights or calculate the weights on the basis of one cubic inch of steel weighing 0.2833 Ib.
Σελίδα 503 - The logarithm of any power of a number is equal to the logarithm of the number multiplied by the exponent of the power.
Σελίδα 599 - Drains. id. ; 8. The main drainage system of every house or building shall be separately and independently connected with the street sewer, where such sewer exists, except where two houses are built together on a lot with a frontage of thirty feet or less., when one connection with main sewer will be allowed ; but there shall be a separate house drain for each house, connected by a "Y...
Σελίδα 536 - In multiple dwellings the walls of all courts, unless built of a light color brick or stone, shall be thoroughly whitewashed by the owner or shall be painted a light color by him, and shall be so maintained. Such whitewash or paint shall be renewed whenever necessary, as may be required by the health officer.
Σελίδα 607 - The branches on vertical lines must be made by "Y" fittings, and be carried to the safe with as much pitch as possible.
Σελίδα 609 - Vent lines shall be connected at the bottom with a soil or waste pipe or with the drain, in such a manner as to prevent accumulation of rust scale and properly to drip the water of condensation.
Σελίδα 536 - ... yards, areaways, vacant rooms and spaces, and all parts and places used in common in a clean, sanitary and safe condition, and shall keep such parts thereof as may reasonably be required by the commissioner of labor properly lighted at all hours or times when said building is in use for factory purposes.
Σελίδα 605 - All sewer, soil and waste pipes must be as direct as possible. Changes in direction must be made with "Y" or half "Y" branches, or one-eighth bends. Offsets in soil or waste pipes will not be permitted when they can be avoided ; nor, in any case, unless suitable provision is made to prevent accumulation of rust or other obstruction. Offsets shall be made with forty-five degree bends, or similar fittings. The use of T-"Y's" (sanitary T's) will be permitted on upright lines only.