Handbook of Applied MathematicsD. Van Nostrand Company, Incorporated, 1941 - 1010 σελίδες |
Αναζήτηση στο βιβλίο
Αποτελέσματα 1 - 3 από τα 34.
Σελίδα 361
... Lath . - Metal lath is manufactured in two general forms , as a wire mesh and as expanded metal ( Figs . 1 and 2 ) . Both forms are protected from corrosion by being painted , japanned or galvanized . Metal lath is not only a base for ...
... Lath . - Metal lath is manufactured in two general forms , as a wire mesh and as expanded metal ( Figs . 1 and 2 ) . Both forms are protected from corrosion by being painted , japanned or galvanized . Metal lath is not only a base for ...
Σελίδα 362
... Lath . - Wire lath is woven from No. 18 to No. 21 Wash- burn & Moen gage wire with 2 and 2 meshes per lineal inch in each direction . Some forms have V - shaped metal stiffeners attached at intervals of 8 inches to provide the fabric ...
... Lath . - Wire lath is woven from No. 18 to No. 21 Wash- burn & Moen gage wire with 2 and 2 meshes per lineal inch in each direction . Some forms have V - shaped metal stiffeners attached at intervals of 8 inches to provide the fabric ...
Σελίδα 364
... lath should be used ? No. 18 gage plain or No. 20 gage reinforced ( Ans . ) Concrete Joisted Floor or Roof 50 25- No ... Lath wired to Furring Channels annealed 12 " Spacing For 3.0lh Expanded Metal Lath " " 34 " " Furring 16 " Channei ...
... lath should be used ? No. 18 gage plain or No. 20 gage reinforced ( Ans . ) Concrete Joisted Floor or Roof 50 25- No ... Lath wired to Furring Channels annealed 12 " Spacing For 3.0lh Expanded Metal Lath " " 34 " " Furring 16 " Channei ...
Περιεχόμενα
SECTION PAGE I INTRODUCTIONHOW TO USE THIS BOOK | 1 |
ARITHMETICSLIDE RULE | 8 |
ALGEBRA | 93 |
Πνευματικά δικαιώματα | |
21 άλλες ενότητες δεν εμφανίζονται
Άλλες εκδόσεις - Προβολή όλων
Συχνά εμφανιζόμενοι όροι και φράσεις
amount amperes angle applied base building calculated called capacity cash cells charged circle circuit column common connected Cosine cost Cotang cubic decimal determined diameter difference direction distance divided electrical equal example expressed factors feet figure Floor foot force formula gear give given heat hour ILLUSTRATION inches interest iron known lath lead length less load magnetic material measured method motor multiplied obtained ohms operation paid paint pipe pitch Plaster pounds pressure problem quantity radiation Receivable resistance roof root sheets shown in Fig side Sine sizes space speed square square feet square inches standard steel Stud supply surface TABLE Tang thickness thread turns unit usually voltage volts wall weight wire