... lbs . · 1380 lbs . 1380 lbs . 790 lbs . 720 lbs . 720 lbs . 240 lbs . 6730 lbs . Hence the total weight of the wall and its load per running foot is 24,036 pounds . The load which one of the piles will support is , by Sanders's rule ...
... lbs . · 1380 lbs . 1380 lbs . 790 lbs . 720 lbs . 720 lbs . 240 lbs . 6730 lbs . Hence the total weight of the wall and its load per running foot is 24,036 pounds . The load which one of the piles will support is , by Sanders's rule ...
Σελίδα 145
... Weight of wall per lineal foot , in tons . and b = Assumed bearing capacity of ground , per square foot ( usually from 1 to 3 tons ) . L Then = W b Required width of foundation , in feet . w = Width of lowest course of footing stones ...
... Weight of wall per lineal foot , in tons . and b = Assumed bearing capacity of ground , per square foot ( usually from 1 to 3 tons ) . L Then = W b Required width of foundation , in feet . w = Width of lowest course of footing stones ...
Σελίδα 146
... foot ) we must consider increased in the same ratio as s , i.e. , b = 2 × 1 = 3 tons . In the column for 3 tons , we find the length 7 feet to agree with 20 inches I - beams 64.0 pounds per foot . uba TO NE Basement floor line Concrete ...
... foot ) we must consider increased in the same ratio as s , i.e. , b = 2 × 1 = 3 tons . In the column for 3 tons , we find the length 7 feet to agree with 20 inches I - beams 64.0 pounds per foot . uba TO NE Basement floor line Concrete ...
Σελίδα 148
... weight on the ground of 2 tons per square foot , it is esti- mated that the building will settle about 4 inches altogether . Piling has been successfully used under several buildings in Chicago , and there seems to be no reason why it ...
... weight on the ground of 2 tons per square foot , it is esti- mated that the building will settle about 4 inches altogether . Piling has been successfully used under several buildings in Chicago , and there seems to be no reason why it ...
Σελίδα 185
... per square inch . Strength and Weight of Colorado Building Stones . The ... foot , 164 pounds . Red Sandstone from Pike's Peak Quarry , Manitou ... pounds , edge 17,181 pounds STRENGTH OF MASONRY . 185.
... per square inch . Strength and Weight of Colorado Building Stones . The ... foot , 164 pounds . Red Sandstone from Pike's Peak Quarry , Manitou ... pounds , edge 17,181 pounds STRENGTH OF MASONRY . 185.
Περιεχόμενα
158 | |
167 | |
187 | |
194 | |
206 | |
233 | |
242 | |
290 | |
297 | |
329 | |
371 | |
383 | |
401 | |
410 | |
422 | |
609 | |
617 | |
620 | |
623 | |
633 | |
650 | |
716 | |
760 | |
769 | |
825 | |
845 | |
1 | |
22 | |
Άλλες εκδόσεις - Προβολή όλων
Συχνά εμφανιζόμενοι όροι και φράσεις
angles arch Architect axis bars beam bending-moment boiler Boston brick Bridge building cast-iron ceiling cement cent centre of gravity chimney column concrete construction Cosin Sine Cosin cube cubic feet cubic foot deflection depth Diam diameter dimensions distance distributed load draw equal factor of safety feet 6 inches fire-proof flange floor formula furnace girder given heat I-beams inches thick iron joint joist length masonry material Mead & White metal mineral wool moment of inertia mortar Multiply pieces pier pipe plaster plates Portland cement pounds per square pressure purlins radiator radius rafter resistance rivets roof safe load shown in Fig side Sine Cosin Sine span square feet square foot square inch steam steel stone strain strength strut surface terra-cotta tile timber truss vertical voussoirs wall Weight per foot width wire wrought-iron Z-BAR
Δημοφιλή αποσπάσματα
Σελίδα 26 - Square Measure 144 square inches = 1 square foot 9 square feet = 1 square yard...
Σελίδα 4 - Multiply the divisor, thus augmented, by the last figure of the root, and subtract the product from the dividend, and to the remainder bring down the next period for a new dividend.
Σελίδα 125 - Force is that which changes, or tends to change, the state of rest or motion of the body acted upon.
Σελίδα 679 - Must have a switch and a cut-out for each wire between the underground conductors and the interior wiring when the two parts of the wiring are connected. These "switches and fuses must be placed as near as possible to the end of the underground conduit, and connected therewith by specially insulated conductors, kept apart not less than two and a half inches.
Σελίδα 681 - ... b. Must not be placed in the immediate vicinity of easily ignitible stuff or where exposed to inflammable gases or dust or to flyings of combustible material.
Σελίδα 679 - Must be so placed in wet places that an air space will be left between conductors and pipes in crossing, and the former must be run in such a way that they cannot come in contact with the pipe accidentally. Wires should be run over, rather than under, pipes upon which moisture is likely to gather or which, by leaking, might cause trouble on a circuit.
Σελίδα 684 - No combination fixture in which the conductors are concealed in a space less than one-fourth inch between the inside pipe and the outside casing will be approved. e. Must be tested for "contacts...
Σελίδα 38 - A Sphere is a solid bounded by a curved surface all points of which are equally distant from a point within called the centre.
Σελίδα 720 - Multiply the diameter of the driver by number of its revolutions, and divide the product by the diameter of the driven, the quotient will be the number of revolutions of the driven.
Σελίδα 675 - Architects are urged, when drawing plans and specifications, to make provision for the channeling and pocketing of buildings, for electric light or power wires, and...