Κρυφά πεδία
Βιβλία Βιβλία
" The conditions of the boiler and furnace in all respects should be, as nearly as possible, the same at the end as at the beginning of the test. The steam pressure should be the same, the water level the same, the fire upon the grates should be the same... "
Finding and Stopping Waste in Modern Boiler Rooms: A Reference Manual to Aid ... - Σελίδα 246
των H. S. B. W. Cochrane Corporation, Philadelphia - 1918
Πλήρης προβολή - Σχετικά με αυτό το βιβλίο

Transactions, Τόμος 5

American Society of Mechanical Engineers - 1884 - 486 σελίδες
...and twenty-four hours whenever practicable. The conditions of the boiler and furnace in all respects should be, as nearly as possible, the same at the end as at the beginning of tliQ,test. The steam pressure should be the same, the water level the same, the fire upon the grates...

Van Nostrand's Engineering Magazine, Τόμος 32

1885 - 566 σελίδες
...and twenty-four hours whenever practicable. 'Hie conditions of the boiler and furnace in all respects should be, as nearly as possible, the same at the end as at the beginning of the test. The steam pressure should be the same, the water level the same, the fire upon the grates should be the...

A Manual of Steam-boilers: Their Design, Construction, and Operation

Robert Henry Thurston - 1888 - 710 σελίδες
...and twenty-four hours whenever practicable. The conditions of the boiler and furnace in all respects should be, as nearly as possible, the same at the end as at the beginning of the test. The steam-pressure should be the same, the water-level the same, the fire upon the grates should be the...

A Treatise on Steam-boiler: Their Strength, Construction, and Economical Working

Robert Wilson - 1889 - 492 σελίδες
...and twenty-four hours whenever practicable. The conditions of the boiler and furnace in all respects should be, as nearly as possible, the same at the end as at the beginning of the test. The steam pressure should be the same, the water level the same, the fire upon the grates should be the...

A Treatise on Steam-boilers: Their Strength, Construction, and Economical ...

Robert Wilson - 1892 - 530 σελίδες
...and twenty-four hours whenever practicable. The conditions of the boiler and furnace in all respects should be, as nearly as possible, the same at the end as at the beginning of the test. The steam pressure should be *he same, the water level the same, the fire upon the grates should be the...

A Manual of Steam-boilers : Their Design, Construction, and Operation: For ...

Robert Henry Thurston - 1890 - 704 σελίδες
...and twenty-four hours whenever practicable. The conditions of the boiler and furnace in all respects should be, as nearly as possible, the same at the end as at the beginning of the test. The steam-pressure should be the same, the water-level the same, the fire upon the grates should be the...

A Handbook of Engine and Boiler Trials and of the Indicator and Prony Brake ...

Robert Henry Thurston - 1890 - 546 σελίδες
...and twenty-four hours whenever practicable. The conditions of the boiler and furnace in all respects should be, as nearly as possible, the same at the end as at the beginning of the test. The steam-pressure should be the same, the water-level the same, the fire upon the grates should be the...

Steam-boiler Construction: A Practical Handbook for Engineers, Boiler-makers ...

Walter S. Hutton - 1891 - 544 σελίδες
...test, it is necessary that the water-level in the boiler and the pressure of the steani be precisely the same at the end as at the beginning of the test. A chemical analysis of the coal should be made, and its calorific value determined by calculation and...

Modern Mechanism: Exhibiting the Latest Progress in Machines, Motors, and ...

Park Benjamin - 1892 - 962 σελίδες
...and twenty-four hours whenever practicable. The conditions of the boiler and furnace in all respects should be, as nearly as possible, the same at the end as at the beginning of the test. The steam pressure should be the same, the water-level the same, the fire upon the grates should be the...

Experimental Engineering and Manual for Testing: For Engineers and for ...

Rolla Clinton Carpenter - 1892 - 830 σελίδες
...and twenty-four hours whenever practicable. The conditions of the boiler and furnace in all respects should be, as nearly as possible, the same at the end as at the beginning of the test. The steam-pressure should be the same, the water-level the same, the fire upon the grates should be the...