Practical carpentry, joinery, and cabinet-making [by P. Nicholson. by P. Nicholson, revised by T. Tredgold. [2 pt. Followed by] The elements of geometry [and] The Metropolitan building act, 1855T. Kelly, 1856 - 216 σελίδες |
Αναζήτηση στο βιβλίο
Αποτελέσματα 1 - 5 από τα 100.
Σελίδα 11
... inches by 360 ; and divide the product by the length AF in inches , and the quotient will express the degrees , and parts of a degree , contained in the angle AFb ; therefore , if AFb WORKING DRAWINGS . 11 V.
... inches by 360 ; and divide the product by the length AF in inches , and the quotient will express the degrees , and parts of a degree , contained in the angle AFb ; therefore , if AFb WORKING DRAWINGS . 11 V.
Σελίδα 12
... inches , and AF be 42 inches , then 360 X 12-102 degrees 51 minutes , for the angle AFb . 42 When only part of a conic surface is to be developed , and ABCD represents the plan of the part , then proceed as before ; and the covering for ...
... inches , and AF be 42 inches , then 360 X 12-102 degrees 51 minutes , for the angle AFb . 42 When only part of a conic surface is to be developed , and ABCD represents the plan of the part , then proceed as before ; and the covering for ...
Σελίδα 12
... inches , a double tenon will be better than a single one . There is no objection to double tenons for bearing purposes , where the tenon is vertical , but they have been very justly objected to for horizontal bearing timbers , on ...
... inches , a double tenon will be better than a single one . There is no objection to double tenons for bearing purposes , where the tenon is vertical , but they have been very justly objected to for horizontal bearing timbers , on ...
Σελίδα 12
... inches from any flue or chimney ; hence the ends of the timbers , as shown in this plan , have no connection with the fire - places , nor with the flues . The flues , in the plans , are indicated by their being shadowed darker than the ...
... inches from any flue or chimney ; hence the ends of the timbers , as shown in this plan , have no connection with the fire - places , nor with the flues . The flues , in the plans , are indicated by their being shadowed darker than the ...
Σελίδα 18
... inches by 1 inch , and thicker where it is bent round the foot of the abutments ; see fig . 5. For convenience , it ... inches in thickness , and 6 inches deep in the middle , and 4 inches deep at the ends . The middle stretcher , A , is ...
... inches by 1 inch , and thicker where it is bent round the foot of the abutments ; see fig . 5. For convenience , it ... inches in thickness , and 6 inches deep in the middle , and 4 inches deep at the ends . The middle stretcher , A , is ...
Άλλες εκδόσεις - Προβολή όλων
Practical Carpentry, Joinery, and Cabinet-Making [by P. Nicholson. by P ... Peter Nicholson Δεν υπάρχει διαθέσιμη προεπισκόπηση - 2018 |
Practical Carpentry, Joinery, and Cabinet-Making [by P. Nicholson. by P ... Peter Nicholson Δεν υπάρχει διαθέσιμη προεπισκόπηση - 2018 |
Συχνά εμφανιζόμενοι όροι και φράσεις
17 Paternoster Row angle angle rib annular vault arch architrave axis balusters bead beam bend boards breadth centre circle circular column construction cornice cutting cylinder depth describe the arc diameter distance divided door draw a curve draw a line drawn edge elevation ellipsis equilateral triangle exhibits face-mould falling-mould feet Figure fixed floor framing frustums groin hand-rail height hinges horizontal hyperbola inches join joinery joint joists Kelly 17 Paternoster king-post length manner Memel method middle moulding number of equal number of points octagon ovolo pannels parabola perpendicular piece of timber pilaster plane plate points of division principal rafters proportion purlin Queen-posts radius ribs riser roof sash sash-frame scantlings semi-circle shows shutters side soffit square stairs steps stile straight line strength supported surbase surface tenon thickness tie-beam triangle truss vertical wall wall-plates width window