The Building Law of the City of Boston: Being Acts of 1907, Chapter 550Master Builders Association, 1907 - 86 σελίδες |
Άλλες εκδόσεις - Προβολή όλων
The Building Law of the City of Boston: Being Acts of 1907, Part 550 Boston (Mass ) Δεν υπάρχει διαθέσιμη προεπισκόπηση - 2015 |
Συχνά εμφανιζόμενοι όροι και φράσεις
Aberthaw adjoining alley or open approved auditorium back air pipes balconies basement board of appeal building commissioner building or structure Carpenter Builder Carter Co cast iron cellar cement columns connected diameter door drain E. R. Co eight inches thick elevator exceed existing tenement house exit feet in height feet in width fifty feet fireproof material fixtures four inches gallery George George W girders Granite Granite Railway half inches house hereafter erected hundred inner court Inspector less than four Linear Foot load Lumber Mason Builders metal lathing mortar open passageway party walls permit piles plastered pounds per square proscenium protected public hall radius of gyration reinforced concrete roof second class buildings SECT sewer shaft skylight space square feet stair halls stairway street stress structure tenement house hereafter theatre three feet trap vent ventilation Warren Brothers waste pipe water-closet compartments Weights per Linear window wire yard
Δημοφιλή αποσπάσματα
Σελίδα 44 - All stairs within the building shall be constructed of fireproof material throughout. Stairs from balconies and galleries shall not communicate with the basement or cellar. All stairs shall have treads of uniform width and risers of uniform height throughout in each flight. Stairways serving for the exit of...
Σελίδα 9 - In multiple dwellings hereafter erected no closet of any kind shall be constructed under any stair-case leading from the entrance story to the upper stories, but such space shall be left entirely open and kept clear and free from incumbrance.
Σελίδα 36 - Every inner court shall be provided with one or more horizontal intakes at the bottom. Such intakes shall always communicate directly with the street or yard, and shall consist of a passageway not less than three feet wide and seven feet high...
Σελίδα 8 - Every chimney flue shall be carried to a height sufficient to protect adjoining buildings from fire and smoke, and, unless the roof is covered with incombustible material, shall extend at least four feet above the highest point of contact with the roof. Every...
Σελίδα 40 - ... durable nonabsorbent material, properly sewer-connected, and with individual traps and properly connected flush tanks providing an ample flush of water to thoroughly cleanse the bowl. Each such water-closet shall be located inside the dwelling or other building...
Σελίδα 37 - ... in every tenement house hereafter erected all rooms, except water-closet compartments and bathrooms, shall be of the following minimum sizes; in each apartment there shall be at least one room containing not less than one hundred and twenty...
Σελίδα 43 - ... the exits in the ratio of one and one-half inches to five running feet. Aisles having seats on one side only, shall be not less than two feet...
Σελίδα 33 - Behind every tenement house hereafter erected, there shall be a yard extending across the entire width of the lot and at every point open from the ground to the sky, unobstructed, except that open iron fire escapes may project not over four feet from the rear line of the house.
Σελίδα 37 - In every tenement house hereafter erected all rooms, except water-closet compartments and bathrooms, shall be of the following minimum sizes : In each apartment there shall be at least one room containing not less than one hundred and twenty square feet of floor area, and each other room shall contain at least seventy square feet of floor area. Each room shall be in every part not less than nine feet high from the finished floor to the finished ceiling; provided that an attic room need be nine feet...
Σελίδα 21 - If cast iron columns are used, each successive column shall be bolted to the one below it by at least four bolts not less than three-fourths of an inch in diameter, and the beams and girders shall be bolted to the columns.