" ... because the method of measurement is specified. The tangent of the average monthly angle of lag is determined by multiplying by the factor 1,732 the ratio between the sum of and the difference between the readings of two single-phase watt-hour meters... "
Practical Mathematics for the Engineer and Electrician - Σελίδα 118
των Elmer Ellsworth Burns, Joseph Gerald Branch - 1912 - 143 σελίδες
Πλήρης προβολή - Σχετικά με αυτό το βιβλίο

Census of Electrical Industries, 1902-: Street Railways and Trolleybus and ...

United States. Bureau of the Census - 1905 - 482 σελίδες
...the readings of two single-phase watt-hour meters installed on the supply circuit. From the tangent of the angle of lag, the cosine of the angle of lag, or power factor, is determined by reference to the standard tables. The "demand," or the figure from...

Elementary Electrical Calculations: A Manual of Simple Engineering ...

Thomas O'Conor Sloane - 1909 - 342 σελίδες
...an alternating current system is equal to the product of the effective current by the effective emf multiplied by the cosine of the angle of lag. The cosine of the angle of lag is called the power factor. Example. Assume an angle of lag of 49° 14' 9" and calculate the power, the...

Hawkins Electrical Guide: Questions, Answers & Illustrations; a ..., Τόμοι 5-6

Nehemiah Hawkins - 1914 - 560 σελίδες
...current and pressure readings or apparent power = 20 X 110 = 2,200 watts The true power is the product of the apparent power multiplied by the cosine of the angle of lag. Cos 45° = .707, hence true power = 2,200 X .707 = 1.555.4 watts. Ones. Does the power factor apply...

Census of Electrical Industries: 1902, 1907, 1912, 1917, 1922, 1927: Central ...

United States. Bureau of the Census - 1915 - 482 σελίδες
...the readings of two single-phase watt-hour meters installed on the supply circuit. From the tangent of the angle of lag, the cosine of the angle of lag, or power factor, is determined by reference to the standard tables. The "demand," or the figure from...

Central Electric Light and Power Stations and Street and Electrical Railways ...

United States. Bureau of the Census - 1913 - 710 σελίδες
...the readings of two single-phase watt-hour meters installed on the supply circuit. From the tangent of the angle of lag, the cosine of the angle of lag, or power factor, is determined by reference to the standard tables. The "demand," or the figure from...

X-ray Physics and Equipment

Fred Jaundrell-Thompson, William John Ashworth - 1965 - 832 σελίδες
[ Λυπούμαστε, το περιεχόμενο αυτής της σελίδας είναι περιορισμένο ]
Προβολή αποσπασμάτων - Σχετικά με αυτό το βιβλίο

Workshop Math

Robert Scharff - 1989 - 470 σελίδες
[ Λυπούμαστε, το περιεχόμενο αυτής της σελίδας είναι περιορισμένο ]
Προβολή αποσπασμάτων - Σχετικά με αυτό το βιβλίο

The National Engineer, Τόμος 12

1908 - 818 σελίδες
...average power (or the true power) is equal to the effective current, times the effective voltage, times the cosine of the angle of lag. The cosine of the angle of lag is called the "power factor," and is the per cent that the "true power" is of the "apparent power." The...