Plumbers and Fitters' Handbook: A Convenient Reference Book for All Persons Interested in Plumbing, Steam Heating, Hot-air Heating, Hot-water Heating, Ventilation, Gas-fitting, Drainage, and SewerageInternational Textbook Company, 1905 - 375 σελίδες |
Αναζήτηση στο βιβλίο
Αποτελέσματα 1 - 5 από τα 36.
Σελίδα xvi
... roofing Float - valve cistern Floor connections , Closet .. 66 slabs , Water - closet .. 66 space per pupil'in ... roofs , Weight of .. Flow of air in flues under natural draft . 46 66 64 66 66 gas . Measurement of pressure and water in ...
... roofing Float - valve cistern Floor connections , Closet .. 66 slabs , Water - closet .. 66 space per pupil'in ... roofs , Weight of .. Flow of air in flues under natural draft . 46 66 64 66 66 gas . Measurement of pressure and water in ...
Σελίδα xxv
... roof . 271 261 140 309 Leeching cesspools 261 Length , Measures of 37 of spiral , Formulas for 58 " steam mains , Equivalent 156 Lengths of mains , Factors for size of different . 157 Lift , Sewage 313 Lifts of pumps , Suction 322 ...
... roof . 271 261 140 309 Leeching cesspools 261 Length , Measures of 37 of spiral , Formulas for 58 " steam mains , Equivalent 156 Lengths of mains , Factors for size of different . 157 Lift , Sewage 313 Lifts of pumps , Suction 322 ...
Σελίδα xxviii
... roofs , Weight of floors .. Paste , Plumbers ' Paul system of steam heating . Person , Heat given off per .. Petroleum 44 Heating value of . Black wrought - iron 46 Block - tin Pipe , Amount of cement required for laying sewer . 44 Cast ...
... roofs , Weight of floors .. Paste , Plumbers ' Paul system of steam heating . Person , Heat given off per .. Petroleum 44 Heating value of . Black wrought - iron 46 Block - tin Pipe , Amount of cement required for laying sewer . 44 Cast ...
Σελίδα xxxiv
... Roof leaders , Sizes of .. Roofing , Flat - seam 161 161 56 57 145 145 145 204 162 309 94 Standing - seam 66 Tin 94 94 46 .. test of plumbing system Roofs , Weight of floors , partitions , and . Room , Proportion of radiating surface to ...
... Roof leaders , Sizes of .. Roofing , Flat - seam 161 161 56 57 145 145 145 204 162 309 94 Standing - seam 66 Tin 94 94 46 .. test of plumbing system Roofs , Weight of floors , partitions , and . Room , Proportion of radiating surface to ...
Σελίδα xxxvii
... roof leaders 309 66 iron - pipe " sinks 66 66 66 " indirect radiation street service pipes . system of steam heating trap - discharge pipes for hot - blast heaters " traps and back - vents , Table of . 66 " vent stacks . Table of 66 ...
... roof leaders 309 66 iron - pipe " sinks 66 66 66 " indirect radiation street service pipes . system of steam heating trap - discharge pipes for hot - blast heaters " traps and back - vents , Table of . 66 " vent stacks . Table of 66 ...
Άλλες εκδόσεις - Προβολή όλων
Plumbers and Fitters' Handbook: A Convenient Reference Book for All Persons ... International Correspondence Schools Δεν υπάρχει διαθέσιμη προεπισκόπηση - 2018 |
Συχνά εμφανιζόμενοι όροι και φράσεις
acetylene air supply apparatus bath bituminous coal Blast Pipe boiler branches brass brick building burners calcium carbide capacity cent circulation closets coal coil connected cubic feet cubic foot decimal point Diam diameter difference direct radiation discharge divided drain drainage equal feedwater heater fixtures floor flow flues flush formula fraction fresh air furnace gallons gauge gauge pressure given number grate surface heater heating surface heating system horsepower hot-water hour inlet iron latent heat length liquid located meter multiplied number of B. T. U. ordinary placed plumber plumbing Pounds pressure pump quantity radiating surface resistance return main return pipe revolutions per minute risers roof sal ammoniac sewage sewer significant figures sizes sprinklers square feet square foot square inches supply tank temperature thick trap tube vacuum valve vaporization velocity vent pipes ventilating volume walls waste pipe water closets weight
Δημοφιλή αποσπάσματα
Σελίδα 33 - Square Measure 144 square inches (sq. in.) = 1 square foot (sq. ft.) 9 square feet = 1 square yard (sq. yd.) 30j square yards = 1 square rod (sq. rd.) 160 square rods = 1 acre (A.) 640 acres = 1 square mile (sq.
Σελίδα 37 - Measures of Length. 10 millimeters (mm.) 1 centimeter (cm.) 10 centimeters 1 decimeter (dm.) 10 decimeters 1 meter (m.) 10 meters 1 dekameter (Dm.) 10 dekameters 1 hectometer (Hm.) 10 hectometers 1 kilometer (Km.) 10 kilometers 1 myriameter (Mm.) 1181.
Σελίδα 35 - LIQUID MEASURE 4 gills (gi.) = 1 pint (pt.) 2 pints = 1 quart (qt...
Σελίδα 34 - SURVEYORS' SQUARE MEASURE. 144. This measure is used by surveyors in computing the area or contents of land. TABLE. 625 Square Links (sq. 1. ) make 1 Pole P. 16 Poles " 1 Square Chain . sq. ch. 10 Square Chains " 1 Acre A. 640 Acres " 1 Square Mile . . sq. mi. 36 Square Miles (6 miles square)
Σελίδα 37 - Measures of Capacity 10 milliliters (ml) =1 centiliter cl 10 centiliters =1 deciliter dl 10 deciliters =1 liter 1 10 liters =1 dekaliter Dl 10 dekaliters =1 hektoliter HI 10 hektoliters =1 kiloliter Kl NOTE — The liter is equal to the volume occupied by 1 cubic decimeter.
Σελίδα 37 - Measures of Weight 10 milligrams (mg) =1 centigram eg 10 centigrams =1 decigram dg 10 decigrams =1 gram g 10 grams =1 dekagram Dg...
Σελίδα 355 - Principals are reponsible for the acts of their agents. Each individual in a partnership is responsible for the whole amount of the debts of the firm, except in cases of special partnership.
Σελίδα 98 - In graduating a Centigrade thermometer, the freezing point is marked 0°, or zero, and the boiling point 100° ; the distance between the freezing and boiling points is divided into 100 equal parts; these equal divisions are carried as far below the freezing point and above the boiling point as desired.
Σελίδα 80 - The pressure per unit of area exerted anywhere upon a mass of liquid is transmitted undiminished in all directions, and acts with the same force upon all surfaces, in a direction at right angles to those surfaces.
Σελίδα 355 - If a note is lost or stolen. It does not release the maker; he must pay It, if the consideration for which it was given and the amount can be proven.